PPT Slide
1-D solution covering ambient BC: TL(z,t) at (xL,yL)
Real Time Thermal Modeling: Methodology
1-D solution covering active BC : TH(z,t) at (xH,yH)
Temperature anywhere on the hood, at any time can be represented by a linear combination of these two 1-D basis functions, TH(z,t) and TL(z,t), weighted by H(x,y)
H(x,y) is obtainable either from empirical measurement (FLIR) or 3D predictive models thermal imagery data (FLIR, etc.)
Th(x,y) – TL(x,y)arbitrary units