Table 6.10 -- EDCS attributes whose label begins with F

Label Definition Attribute value type EQ label Code
FABRICATION_TYPE The type of a fabrication industry <OBJECT>. ENUMERATION   365
FACET_TYPE The type of <OBJECT> represented by a <FACET>. ENUMERATION   366
FARMING_METHOD The agricultural practice in use within an agro-ecosystem; the farming method. ENUMERATION   367
FENCE_TYPE The type of a <FENCE>. ENUMERATION   368
FERRY_CROSSING_LENGTH The <<LENGTH>> of a <FERRY_CROSSING> between points on opposite <SHORE>s. REAL LENGTH 369
FERRY_CROSSING_TIME The usual <<TIME_QUANTITY>> taken for a crossing by <FERRY>, including typical loading and unloading times. REAL TIME 370
FERRY_ROUTE_TYPE The type of <ROUTE> which a <FERRY> follows. ENUMERATION   371
FIELD_PATTERN The geometric layout used in placing seeds or young <PLANT>s on a <TRACT> used for agriculture; the field pattern. ENUMERATION   372
FIGHTER_WINGED_AIRCRAFT_TYPE The type of a <FIGHTER_WINGED_AIRCRAFT>. ENUMERATION   373
FINE_SCALE_CORRELATION_LENGTH The correlation length of the <<FINE_SCALE_ROUGHNESS>> of a <SURFACE>. REAL LENGTH 374
FINE_SCALE_ROUGHNESS The fine-scale (within one or two orders of magnitude of the <<WAVELENGTH>> of the electromagnetic radiation of concern) roughness of a <SURFACE>, expressed as the standard deviation of the surface variation. REAL LENGTH 375
FIRE_ESCAPE_EXTENDED An indication that the retracting, lowest section of a <FIRE_ESCAPE> is extended for use. BOOLEAN   376
FIRE_POWER_DAMAGE A number between 0 and 1 inclusive representing the linearly-scaled fraction of the extent of physical injury/damage to an <OBJECT> affecting its capability to project firepower. Zero means not capable at all and one means fully capable. REAL PURE_NUMBER 377
FISHING_FACILITY_TYPE The type of a <FISHING_FACILITY>. ENUMERATION   378
FISHING_VESSEL_DENSITY The areal density of <FISHING_BOAT>s. REAL AREAL_ENTITY_DENSITY 379
FLOODLIT An indication that a <SET> of floodlights are illuminating an <OBJECT>. BOOLEAN   380
FLOOR_CONSTRUCTION_TYPE The type of material and/or techniques used to construct a <FLOOR>. ENUMERATION   381
FLOOR_COVERING_TYPE The type of the covering of a <FLOOR>. ENUMERATION   382
FLOOR_LEVEL_COUNT The number of <FLOOR_LEVEL>s for accommodating <HUMAN>s or <EQUIPMENT> in a <BUILDING>, possibly different from the number of stories in the <BUILDING>. <FLOOR_LEVEL>s may include underground <FLOOR_LEVEL>s as well as above ground <FLOOR_LEVEL>s; the floor level count. COUNT   383
FLOOR_LEVEL_ID The numeric identifier of a <FLOOR_LEVEL>. INDEX   384
FLOW_DIRECTION The <DIRECTION> of flow. REAL PLANE_ANGLE 385
FOG_COVERAGE_FRACTION A number between 0 and 1 inclusive representing the linearly-scaled fraction of the areal fraction of a <REGION> that is covered by <FOG>, as seen from above. Zero means no coverage at all and one means complete coverage. REAL PURE_NUMBER 386
FOG_DETECTOR_LIGHT_PRESENT An indication that an <OBJECT> has an associated detector light for <FOG>. BOOLEAN   387
FOG_EXTINCTION_COEFFICIENT The <<EXTINCTION_COEFFICIENT_LOSS>> due to <FOG>. REAL LINEAR_ENERGY_TRANSFER 388
FOG_PRESENT An indication that <FOG> is present. BOOLEAN   389
FOG_PROBABILITY The probability of the occurrence of <FOG>. REAL PURE_NUMBER 390
FOG_SIGNAL_GENERATION_TYPE The type of mechanism of signal generation in the presence of <FOG>. ENUMERATION   391
FOG_THICKNESS The height of a bank of <FOG> relative to the local <TERRAIN>, where the base of the <FOG> is assumed to be at ground level; fog thickness. REAL LENGTH 392
FOLIAGE_STATE The state of the foliage within a delineated <REGION>. ENUMERATION   393
FORMATION_RUNNING_LIGHT-
_INTENSITY
A number between 0 and 1 inclusive representing the linearly-scaled fractional intensity of the external <LIGHTING> used to maintain spatial relationships with/by <VEHICLE>s; the formation, running, or tail light intensity. Zero means unlit and one means maximum intensity. REAL PURE_NUMBER 394
FRACTIONAL_CONTENT A number between 0 and 1 inclusive representing the linearly-scaled fraction of the total composition of an <OBJECT>. Zero means that there is no contribution and one means that the <OBJECT> is homogeneous. REAL PURE_NUMBER 395
FREQUENCY The frequency of an audio, electromagnetic, or light wave. REAL FREQUENCY 396
FREQUENCY_INDEPENDENT-
_ACOUSTIC_SCATTERING_LEVEL
In a <WATER_BODY>, the frequency-independent acoustic scattering level. REAL FIELD_OR_POWER_LEVEL_DIFF 397
FRIGATE_TYPE The type of a <FRIGATE>. ENUMERATION   398
FRONT_AND_AXIS_REFERENCE The association of the front, or long, axis of an <OBJECT> to an axis of a reference local orthonormal coordinate system. ENUMERATION   399
FROZEN_SOIL_LAYER_BOTTOM_DEPTH The <<DEPTH>> from the <TERRAIN> to the base of a layer of frozen <SOIL>. REAL LENGTH 400
FROZEN_SOIL_LAYER_TOP_DEPTH The <<DEPTH>> from the <TERRAIN> to the top of a layer of frozen <SOIL>. REAL LENGTH 401
FROZEN_SURFACE_COVER_TYPE The type of frozen <PRECIPITATION> and/or frozen <WATER> that is present covering a <SURFACE>. ENUMERATION   402
FUEL_FACILITIES_AVAILABLE The type of fuel <FACILITY>s available at or in the near vicinity. ENUMERATION   403
FUNCTIONAL_RUNWAY_COUNT The number of fully functional <RUNWAY>s at an <AERODROME>; the functional runway count. COUNT   404
FURNITURE_TYPE The type of <FURNITURE>. ENUMERATION   405

separator bar

http://www.iso.ch/iso/en/ittf/PubliclyAvailableStandards/ISO_IEC_18025_Ed1.html