Table 6.9 — EAs whose label begins with E
Label | Concept definition | Attribute value type | EQ label | Code |
ECOSYSTEM_TYPE | The type of an ecosystem based on a combination of land cover, floristic properties, climate, and physiognomy. | ENUMERATION | 321 | |
EDUCATIONAL_BUILDING_TYPE | The type of an educational <BUILDING>. | ENUMERATION | 322 | |
ELECTRON_DENSITY | The number of electrons per unit <<VOLUME>>; the electron density. | REAL | VOLUMETRIC_ENTITY_DENSITY | 323 |
ELECTRONIC_WATERBODY_FLOOR- _DEPTH |
The <<DEPTH_OF_WATERBODY_FLOOR>> obtained by electronic depth measuring instruments. | REAL | LENGTH | 324 |
ELEV_ELECTRICAL_CABLE_ICING- _SAG |
The value of the maximum variation in the vertical clearance of an <ELEVATED_ELECTRICAL_CABLE> due to an accumulation of <ICE>; the elevated electrical cable icing sag. | REAL | LENGTH | 325 |
ELEV_ELECTRICAL_CABLE- _MINIMUM_HEIGHT |
The minimum <<HEIGHT_AGL>> of an <ELEVATED_ELECTRICAL_CABLE> above the underlying <PLANETARY_SURFACE>; the elevated electrical cable minimum clearance. | REAL | LENGTH | 326 |
ELEV_ELECTRICAL_CABLE_PYLON- _SPACING |
The spacing distance between adjacent <PYLON>s along an <ELEVATED_ELECTRICAL_CABLE>. | REAL | LENGTH | 327 |
ELEV_ELECTRICAL_CABLE_SAG | The maximum vertical distance from the height of an <ELEVATED_ELECTRICAL_CABLE> at a connection to a <PYLON> to the lowest point of the <ELEVATED_ELECTRICAL_CABLE>; the elevated electrical cable sag. | REAL | LENGTH | 328 |
ELEV_ELECTRICAL_CABLE- _SEGMENT_COUNT |
The number of straight segments that may be used to approximate the catenary shape of an <ELEVATED_ELECTRICAL_CABLE> between adjacent <PYLON>s; the elevated electrical cable segment count. | COUNT | 329 | |
ELEV_ELECTRICAL_CABLE_TYPE | The type of suspension of an <ELEVATED_ELECTRICAL_CABLE>. | ENUMERATION | 330 | |
ELEVATION | The distance above a <SURFACE_DATUM>. | REAL | LENGTH | 331 |
ELEVATION_ACCURACY_STATEMENT | A statement of the accuracy of an <<ELEVATION>>. | ENUMERATION | 332 | |
ELEVATION_ANGLE | The <<VECTOR_ELEV_ANGLE_LOCAL>> from the horizontal plane at the observer's location, to either a <LINE> passing through the observer, or a vector relative to the observer, or the direction from the observer to an <OBJECT> or <LOCATION>; the elevation angle. | REAL | PLANE_ANGLE | 333 |
EM_BAND | The scientifically-accepted designation for a range of <<FREQUENCY>>s within the electromagnetic spectrum; the electromagnetic band. | ENUMERATION | 334 | |
EM_EVAPORATIVE_DUCT_HEIGHT | The <<HEIGHT_AGL>> of the top of a <ELECTROMAGNETIC_REFRACTIVE_EVAPORATIVE_DUCT>. | REAL | LENGTH | 335 |
EM_POLARIZATION_TYPE | The type(s) of electromagnetic polarization established by an <AERIAL> of an emitter and/or a receiver. | ENUMERATION | 336 | |
EM_PROPAGATION_CONDITION | The type of condition causing variation in the propagation path of electromagnetic energy due to interaction of the emitted energy with the vertical density gradient of the <ATMOSPHERE>. | ENUMERATION | 337 | |
EM_PULSE_DURATION | The quantity of time (duration) of an electromagnetic pulse, as measured between the half-power points. | REAL | TIME | 338 |
EM_PULSE_PEAK_POWER | The peak power of an electromagnetic pulse. | REAL | POWER | 339 |
EM_PULSE_TOTAL_ENERGY | The total energy of an electromagnetic pulse. | REAL | ENERGY | 340 |
EM_TRANSMISSION_LOSS | The electromagnetic <<TRANSMISSION_LOSS>>. | REAL | FIELD_OR_POWER_LEVEL_DIFF | 341 |
EMISSIVITY | The ratio of the power emitted by an <OBJECT> at a given <<TEMPERATURE>> to the power emitted if the body obeyed Planck's radiation law (black body emission); the emissivity. | REAL | PURE_NUMBER | 342 |
EMITTANCE_AZIMUTH_GEODETIC | The <<VECTOR_AZIMUTH_GEODETIC>> toward which light is emitted (the <DIRECTION> of the Poynting vector). | REAL | PLANE_ANGLE | 343 |
EMITTANCE_AZIMUTH_LOCAL | The <<VECTOR_AZIMUTH_LOCAL>> toward which light is emitted (the <DIRECTION> of the Poynting vector). | REAL | PLANE_ANGLE | 344 |
EMITTANCE_AZIMUTH_MAGNETIC | The <<VECTOR_AZIMUTH_MAGNETIC>> toward which light is emitted (the <DIRECTION> of the Poynting vector). | REAL | PLANE_ANGLE | 345 |
EMITTANCE_ELEV_ANGLE- _HORIZONTAL |
The <<VECTOR_ELEV_ANGLE_HORIZONTAL>> toward which light is emitted (the <DIRECTION> of the Poynting vector). | REAL | PLANE_ANGLE | 346 |
EMITTANCE_ELEV_ANGLE_LOCAL | The <<VECTOR_ELEV_ANGLE_LOCAL>> toward which light is emitted (the <DIRECTION> of the Poynting vector). | REAL | PLANE_ANGLE | 347 |
EMITTED_DIFFUSE_LIGHT_SCALED- _INTENSITY |
A number between 0 and 1 inclusive representing that linearly-scaled fractional light intensity that leaves the <SURFACE> of an <OBJECT> in all <DIRECTION>s with equal magnitude. Zero means minimum intensity and one means maximum intensity. | REAL | PURE_NUMBER | 348 |
EMITTED_SPECULAR_LIGHT- _SCALED_INTENSITY |
A number between 0 and 1 inclusive representing that linearly-scaled fractional light intensity that leaves the <SURFACE> of an <OBJECT> in a particular <DIRECTION>. Zero means minimum intensity and one means maximum intensity. | REAL | PURE_NUMBER | 349 |
ENCLOSURE_MAXIMUM_HEIGHT | The maximum vertical distance from <FLOOR> to <ROOM_CEILING> of a <BUILDING> compartment (for example: a <ROOM> and/or a <FLOOR_CRAWL_SPACE>; the enclosure maximum height. | REAL | LENGTH | 350 |
ENCLOSURE_MINIMUM_HEIGHT | The minimum vertical distance from <FLOOR> to <ROOM_CEILING> of a <BUILDING> compartment (for example: a <ROOM> and/or a <FLOOR_CRAWL_SPACE>; the enclosure maximum height. | REAL | LENGTH | 351 |
ENGINE_SMOKE_RATE | The <<SMOKE_RATE_FRACTION>> of a motor/engine/propulsion <SYSTEM> in an <OBJECT>. | REAL | PURE_NUMBER | 352 |
ENGINEER_TRENCH_TYPE | The type of an <ENGINEER_TRENCH>. | ENUMERATION | 353 | |
ENTRANCE_AND_OR_EXIT_COUNT | The number of <STRUCTURE_ENTRANCE_AND_OR_EXIT>s of a <STRUCTURE>; the entrance and/or exit count. | COUNT | 354 | |
ENTRANCE_COUNT | The number of <STRUCTURE_ENTRANCE>s of a <STRUCTURE>; the entrance count. | COUNT | 355 | |
EXIT_COUNT | The number of <STRUCTURE_EXIT>s of a <STRUCTURE>; the exit count. | COUNT | 358 | |
EXPLOSIVE_MINE_DENSITY | The areal density of <EXPLOSIVE_MINE>s within a <MINEFIELD>. | REAL | AREAL_ENTITY_DENSITY | 359 |
EXPLOSIVE_MINE_TYPE | The type of an <EXPLOSIVE_MINE>. | ENUMERATION | 360 | |
EXTERIOR_LIGHTING_INTENSITY | A number between 0 and 1 inclusive representing the linearly-scaled fractional intensity of the general external <LIGHTING> of an <OBJECT>. Zero means unlit and one means maximum intensity. | REAL | PURE_NUMBER | 361 |
EXTERIOR_WALL_CONSTRUCTION- _TYPE |
The type of <MATERIAL> and/or techniques used to construct an <EXTERIOR_WALL>. | ENUMERATION | 362 | |
EXTERIOR_WALL_FORTIFICATION | The <MATERIAL>s and/or techniques used to fortify an <EXTERIOR_WALL>. | ENUMERATION | 363 | |
EXTERIOR_WALL_THICKNESS | The <<THICKNESS>> of an <EXTERIOR_WALL>. | REAL | LENGTH | 364 |
EXTERNAL_PAINT_SCHEME | The applied external paint scheme of an <OBJECT>. | ENUMERATION | 365 | |
EXTERNAL_WINDOW_COVERING | The type of the external covering of a <WINDOW>. | ENUMERATION | 366 | |
EXTINCTION_COEFFICIENT | For radiation propagating through a medium, the fractional depletion of <<RADIANCE>> per unit path length; the extinction coefficient loss. | REAL | LINEAR_ENERGY_TRANSFER | 367 |
EXTINCTION_COEFFICIENT_LEVEL | The vertical displacement above a <SURFACE_DATUM> identified by an <<ATM_VERTICAL_REFERENCE>> at which a given value of <<EXTINCTION_COEFFICIENT>> occurs; the extinction coefficient level. | REAL | GEOPOTENTIAL_ENERGY_LENGTH | 368 |
EXTINCTION_COEFFICIENT- _WAVELENGTH |
The electromagnetic <<WAVELENGTH>> for an <<EXTINCTION_COEFFICIENT>>. | REAL | LENGTH | 369 |
EXTRACTION_MINE_TYPE | The type of an <EXTRACTION_MINE>. | ENUMERATION | 370 | |
EXTREME_HIGH_AIR_TEMPERATURE | The maximum (extreme) of a <SET> of <<MAXIMUM_AIR_TEMPERATURE>>s for a <<TIME_QUANTITY>>; a maximum high air temperature. | REAL | THERMO_TEMPERATURE | 371 |
EXTREME_LOW_AIR_TEMPERATURE | The minimum (extreme) of a <SET> of <<MINIMUM_AIR_TEMPERATURE>>s for a <<TIME_QUANTITY>>; a minimum low air temperature. | REAL | THERMO_TEMPERATURE | 372 |
http://www.iso.ch/iso/en/ittf/PubliclyAvailableStandards/ISO_IEC_18025_Ed1.html